Paste
Copy
Cut
Options
  • Pregunta: Please I need help with this exercise! Another of the projects contracted by the municipality of Aquímequedo consists of the design of a new fully mixed activated sludge secondary treatment plant, which will receive the water from the existing plant that only provides primary treatment. We will proceed with the design of a rectangular aeration tank assigned

    Please I need help with this exercise!

    Another of the projects contracted by the municipality of Aquímequedo consists of the design of a new fully mixed activated sludge secondary treatment plant, which will receive the water from the existing plant that only provides primary treatment. We will proceed with the design of a rectangular aeration tank assigned to you. The following data was provided by the municipality associated with the operation of the existing primary plant which you will use for the design of the aeration tank, as necessary:

    student submitted image, transcription available below​​​​​​​

    Muestra el texto de la transcripción de la imagen
  • Chegg Logo
    Esta pregunta aún no se resolvió!
    ¿No es lo que buscas?
    Envía tu pregunta a un experto en la materia.
    Texto de la transcripción de la imagen:
    Orro de los proyectoh contratado por ol municipio de Aquimequedo onnsiste en ef diseño de una aueva planta de tratamiento secundaria do uguas usadas de lodos activados del tipo completamente mezelado la cual recibirá las ageas de In planta existente que énicamente provee tratamiento primario, Se procederá cont el diseño de un tanque de aireación rectangular asignadoa usted. Los stguientes datos fueron provistos por el municipto asociados con la operación de la planta primaria existente los ceales usted utilizară para el diseho del tanque de airención, seguin sea necesario: - Flujo Peomedio Diseño- 0.088 m3/s(2.0MGD) - Elajo Pico Disen̄o- 0.131 m3/s - BODs Salida Planta Primaria- 102 mg'l - S5lidos Suspendidos Totales (TS8) Salida Planta Primaria- 137mg/ - Temperatura Agua - 2θC F1 permiso de descar ga para la planta nueva requiere que: - BODi. Efluente- 30mg/ - Solidos Suspendidos Totales (TSS) Eflueate-s31) meil Como parte del diseño se utilizarán los siguientes datos los cuales usted considerarai, segin sen necesario. - K5=110mg/BOD. - μm=2.4/dia - kd=0,045 /dia - Concentracion MLVSS =2,800mg / - MIL VSSAISS =0.7 - Concentración TSS en Lodos de Recirculación ( RAS )=9,300mg/ - Y=0.5mg VSS mg BODs - BODsBOD Danine 0.65 Asuma: - 65% de BODi en los TSS de entrada no son biodegradable - Profundidad Tanque de Aeración =12ft. 1% contenido de solidos =0.01 kg/kg Defermine: a. Tiempo de Retención Orgánica (θc) (dias) (20%) b. Volumen de Reactor (V)(gal)(200%) c. Dimensiones del Tanque (ff) (ancho, largo, profundidad); razón de largo:ancho 2.5:1) (15:) d. Cantidad de lodos a desechar (Qw)(mingal)(15%)
Texto de la transcripción de la imagen:
Orro de los proyectoh contratado por ol municipio de Aquimequedo onnsiste en ef diseño de una aueva planta de tratamiento secundaria do uguas usadas de lodos activados del tipo completamente mezelado la cual recibirá las ageas de In planta existente que énicamente provee tratamiento primario, Se procederá cont el diseño de un tanque de aireación rectangular asignadoa usted. Los stguientes datos fueron provistos por el municipto asociados con la operación de la planta primaria existente los ceales usted utilizară para el diseho del tanque de airención, seguin sea necesario: - Flujo Peomedio Diseño- 0.088 m3/s(2.0MGD) - Elajo Pico Disen̄o- 0.131 m3/s - BODs Salida Planta Primaria- 102 mg'l - S5lidos Suspendidos Totales (TS8) Salida Planta Primaria- 137mg/ - Temperatura Agua - 2θC F1 permiso de descar ga para la planta nueva requiere que: - BODi. Efluente- 30mg/ - Solidos Suspendidos Totales (TSS) Eflueate-s31) meil Como parte del diseño se utilizarán los siguientes datos los cuales usted considerarai, segin sen necesario. - K5=110mg/BOD. - μm=2.4/dia - kd=0,045 /dia - Concentracion MLVSS =2,800mg / - MIL VSSAISS =0.7 - Concentración TSS en Lodos de Recirculación ( RAS )=9,300mg/ - Y=0.5mg VSS mg BODs - BODsBOD Danine 0.65 Asuma: - 65% de BODi en los TSS de entrada no son biodegradable - Profundidad Tanque de Aeración =12ft. 1% contenido de solidos =0.01 kg/kg Defermine: a. Tiempo de Retención Orgánica (θc) (dias) (20%) b. Volumen de Reactor (V)(gal)(200%) c. Dimensiones del Tanque (ff) (ancho, largo, profundidad); razón de largo:ancho 2.5:1) (15:) d. Cantidad de lodos a desechar (Qw)(mingal)(15%)